Global Implementation Group                

Providing Professional Services and Technical Consulting for Electronic Security Systems, Fault Tolerant Computer Systems and much more...

GIG Home Up

NEWS:  Re*Cure Version 1.60 / Re*Spect - Reporting, Testing and More


 

GIG Home
Up

 

Re*Cure Reporting System© - “Recure” - To arrive at; to reach; to attain.

Updated March 30, 2009!

VERSION 1.60 with "Re*Cure - ReSpect" - Testing and Commissioning Database Now Available.

Full Overview Please Select -
ReCure/ReSpect Overview Document

Some of the reports available in The Re*Cure Reporting System© Version 1.60 Include:

Hardware - Physical Device Reports

  • Full I-Star Device Report
    This report results in a listing of all devices configured to an I-Star and the connection points to which they are connected.
     
  • Customer Reader Report
    This reports yields an I-Star by I-Star report with Reader Name Filter to provide a simple report of reader assignments.
     
  • Input Reports (ACM and I8/RM4)
    These reports yields reports that outline Inputs per I-Star and give indication of where alarms and other input points are connected.

Logical - Event Reports

  • Events Offline
    Events Administratively OFFLINE
    Provides Report of Events Programmed as OFFLINE in Administration Client.
     
  • Events In-Test
    Provides Report of Events Programmed as OFFLINE AND that have the label "In-Test" typed into the Event Instructions.
     
  • Events Not Monitored By On-Line Event Group
    Provides Report of Events NOT Assigned to On-Line Events Group and Subordinate Monitoring Privilege.

Activity Based Reports - Top Active Items

  • Enhanced Reporting INPUT Report
    Provides a list of Inputs that have entered the history database in descending order of activation count; selectable by activation count threshold.
    This report can be invaluable to identify Input Points that either need service attention, or may need to be reprogrammed to avoid nuisance alarms and operator distraction. 
     
  • Enhanced Reporting EVENT Report
    Provides a list of Inputs that have entered the history database in descending order of activation count; selectable by activation count threshold.
    This report can be invaluable to identify Events that either need service attention, or may need to be reprogrammed to avoid nuisance alarms and operator distraction. 
     
  • Enhanced Reporting DOOR Report
    Provides a list of Inputs that have entered the history database in descending order of activation count; selectable by activation count threshold.
    This report can be invaluable to identify Door Open/Held, REX Devices and configuration issues that either need service attention, or may need to be reprogrammed to avoid nuisance alarms and operator distraction. 
     
  • Device Communication Failure Report
    Provides a report outlining devices that are experiencing communication problems and may require service attention.
     
  • 24 Hour (S) Sensitive Area Event Activity Report
    This report generates a report outlining the new activation of Events that carry the text (S) in them; these Events are tagged to indicate sensitive area and are of extreme concern.  This report will (when automated)
     
  • 24 Hour Tamper Report
    Provides a report of devices that have registered a tamper signal over the last 24 hours.

Misc. Reports

  • CCTV Action Detail Report
    Provides a list of programmed CCTV Actions and their respective parameters.
     
  • Events the Call CCTV Actions
    Provides a list of Events that Call CCTV Actions and their respective parameters.
     
  • Group Definition Detail Report
    Provides a listing of Objects Assigned to C*Cure 800/8000 Groupings (such as Door Groups or Event Groups) as well as indicating if these respective events are assigned to be downloaded to an I-Star controller.  This report is searchable by Group Name and can be very useful to determine system loading and Group Relationships
     
  • Group Record Count Report
    Provides a count of assigned C*Cure Objects Assigned to “Groups”.   Useful to determine system loading and database table sizes.

NEW IN VERSION 1.60 –

ReSpect – Inspection and Testing Database

New in Re*Cure version 1.60 and above is the addition of “ReSpect” Testing and Commissioning Database.  This database can be used to generate simple blank Door and Input testing reports to linked C*Cure 800/8000 Doors and Inputs as well as offering a database linkage to register and track testing results. 

Additionally, the ReSpect system can allow configuration details of the physical equipment in the field to be recorded and stored for reference (such as lock type and voltage, power circuit numbers, etc…).  This could be helpful not only to establish as-built records, but also to direct technicians in the field (lessen service and downtime).

 

1 - Example Door Detail and Testing Form

ReSpect Feature Overview 

*          Blank Report Generation
Produce detailed blank report documentation for field testing and reference.  These blank forms can also be used as an inspection and acceptance hardcopy as performed in the field.  Installing agents as well as owners could take these to the area and test with individuals to later be used as the formal record of the testing in written form.
 

*          Door Testing Form (as shown above)
Utilized in ReSpect to add details to doors regarding the physical installation as well as to record testing results and generate selectable door testing history reports.
 

*          Input Testing Form
Utilized in ReSpect to record input (that are linked to C*Cure Events that Require Acknowledgement) testing results.  Also used to generate selectable input testing history reports.
 

*          ReSpect History Reports
Generate reports that outline the history recorded into the ReSpect testing and commissioning system.

Sort by and filter by date range, controller name and even door or input name.

The example below outlines how you could produce a report on only “Sensitive Doors” (Doors that name contain “(S)”) that are attached to any I-Star Controller with “P1” in its name.


 2 - Testing History Form

Microsoft Windows™, Access™ and Excel™ are Registered Trademarks of the Microsoft Corporation.
C*Cure 800/8000 System™ is a Registered Trademark of the Software House / TYCO Corporation.


Sample Screens

Sample Reports
 



 


 


Send mail to HB@Gigsecurity.com with questions or comments about this web site.
Last modified: 11/30/09